Powerless Temperature Monitoring with Single Output
SPECIFICATIONS
Power Requirement No power required to operate.
Operating Temperature Alarm Use: 50 to 130° F (10 to 54° C); non-condensing environments only.
Alarm contacts may not function outside of this range.
Display Use: -30 to 130° F (-34 to 54° C); non-condensing environments only.
Low Limit Adjust Range -30 to 120° F (-34 to 49° C)
High Limit Adjust Range -20 to 130° F (-29 to 54° C)
Temp Accuracy ±3°F (±1.7° C)
Temp Response Time TC = 14 minutes
Temp Sensing Element Bimetallic Coil
Outputs Gold plated N.O. dry contacts (Not for high voltage use.)
Contact Output Rating 50mA @ 12VDC
Weight 6.5 oz (.18 kg)
Dimensions 6.25 x 3.75 x 2” (15.9 x 9.5 x 5.1 cm)
Material ABS
Mounting Key slot
CONTENTS
This package contains:
One (1) TA-1
Two (2) mounting screws and two (2) wall anchors
Mounting template (inside this Instruction Guide)
One (1) Installation/Operating Instructions Guide
TA-1
ONE YEAR LIMITED WARRANTY
Winland Electronics, Inc. (“Winland”) warrants to the end user/purchaser that each product of its manufacture shall be free from defects in material
and factory workmanship for a period of one year from the date of purchase, when properly installed and operated under normal conditions
according to Winland’s instruction.
Winland’s obligation under this warranty is limited to correcting, without charge, at its factory any part or parts thereof which shall be returned to
the factory, by the original purchaser, transportation charges prepaid, within one year of the date of purchase and which upon examination, shall
disclose to Winland’s satisfaction to have been originally defective. Correction of such defects by repair to, or supplying replacements for, defective
parts shall constitute fulfillment of all Winland’s obligations to purchaser under this limited warranty. Repair service performed by Winland after one
year from date of purchase will be for a reasonable service charge.
This limited warranty shall not apply to any of Winland’s products which have been subject to misuse, negligence or accident or which have been
repaired or altered outside of Winland’s factory. The warranty is void if the Product’s housing or cover is removed.
Winland shall not be liable for loss, damage or expense resulting, directly or indirectly, from the use of its products or any other cause.
This warranty shall be null and void in its entirety if: (i) the product is altered or modified in any way that is not consistent with the manufacturer’s
instructions, or (ii) the product is used with or connected to a device: (a) that such product is not intended to be used with or connected to, (b) is not
otherwise consistent with the manufacturer’s instructions, or (c) is not otherwise approved by the manufacturer.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF
MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES, NON-INFRINGEMENT AND TITLE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING,
USAGE OF TRADE OR OTHERWISE. ALL OTHER REPRESENTATIONS MADE TO THE END USER/PURCHASER BY ANY OTHER PARTY ARE ALSO EXCLUDED.
WINLAND SHALL NOT BE LIABLE TO ANY PERSON FOR INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY DESCRIPTION, WHETHER
ARISING OUT OF WARRANTY OR OTHER CONTRACT, NEGLIGENCE OR OTHER TORT, OR OTHERWISE. Under no circumstances shall Winland’s liability
under this limited warranty exceed the purchase price paid by the end user/purchaser for the product.
No person, agent or dealer is authorized to give warranties on behalf of Winland nor to assume for Winland any other liability in connection with
any of its products.
© 2012 Winland Electronics, Inc.
D-011-0113 Rev B (08/2012)
Tech Support 8:00am - 5:00pm Central Time
(800) 635-4269 • +1-507-625-7231 P
www.winland.com
WEEE Product Recovery/Recycling for EU Customers
In an effort to improve waste management in the European Union, the European Union has enacted directive 2002/96/EC on Waste Electrical and
Electronic Equipment (WEEE Directive). According to the WEEE Directive, Winland Electronics must take back waste electrical or electronic equipment
covered under the WEEE Directive, at its cost, for all product it puts on the market after July 1, 2006. The Return Process: Contact Winland via our web
site at www.winland.com.
Applicable Directives
RoHS Directive 2002/95/EC; WEEE Directive 2002/96/EC
Statement of Compliance:
Winland Electronics, Inc. hereby declares this device is in compliance with all the applicable Directives 2002/95/EC, 2002/96/EC. This device is
considered a passive EM device and is thereby excluded from the scope of the EMC directive 89/336/EEC and Low Voltage Directive 73/23/EEC.
Symbols on the Product or Manual Labeling
For product disposal, ensure the following:
• Do not dispose of this product as unsorted municipal waste.
• Collect this product separately.
• Use collection and return systems available to you.
WEEE Waste Electrical and Electronic Equipment
RoHS Restriction of Hazardous Substances
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - ONE YEAR LIMITED WARRANTY

Powerless Temperature Monitoring with Single OutputSPECIFICATIONSPower Requirement No power required to operate.Operating Temperature Alarm Use: 50

Seite 2 - Figure 2 Figure 3 Figure 4

INTRODUCTIONThe Temp˚Alert ® has been designed for reliable monitoring of non-condensing (indoor only) environment areas where high and low temperatur

Seite 3

INTRODUCTIONThe Temp˚Alert ® has been designed for reliable monitoring of non-condensing (indoor only) environment areas where high and low temperatur

Seite 4

Powerless Temperature Monitoring with Single OutputSPECIFICATIONSPower Requirement No power required to operate.Operating Temperature Alarm Use: 50